EJA430E Gauge Pressure Transmitter
Brand: YokogawaThe EJA430E is a high-performance gauge pressure transmitter used to measure liquid, gas, or steam pressure. Featuring Yokogawa DPharp sensor technology, the EJA430E delivers measurements accurately, quickly, and reliably.
EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certified as complying with SIL 2 safety requirements.
Specifications
Brand
Accuracy
- ± (0.005 + 0.0035 URL/Span)% of Span for High Accuracy (Includes the Effects of Terminal-Based Linearity, Hysteresis & Repeatability) - Capsule A & B
- ± (0.005 + 0.0049 URL/Span)% of Span for High Accuracy (Includes the Effects of Terminal-Based Linearity, Hysteresis & Repeatability) - Capsule H
- ± (0.01 + 0.0045 URL/Span)% of Span (Includes the Effects of Terminal-Based Linearity, Hysteresis & Repeatability) - Capsule A & B
- ± (0.01 + 0.0063 URL/Span)% of Span (Includes the Effects of Terminal-Based Linearity, Hysteresis & Repeatability) - Capsule H
- ± 0.04% of Span for High Accuracy (Includes the Effects of Terminal-Based Linearity, Hysteresis & Repeatability)
- ± 0.055% of Span (Includes the Effects of Terminal-Based Linearity, Hysteresis & Repeatability)
Adjustment
- External Zero-Adjustment Screw
- Push-Buttons
Alarm
- Down-Scale: -5%, 0.8 Vdc or less - for 1-5 V HART
- Down-Scale: -5%, 3.2 mA DC or less - for 4-20 mA HART/BRAIN
- Up-Scale: 110%, 21.6 mA DC or more (Standard) - for 4-20 mA HART/BRAIN
- Up-Scale: 110%, 5.4 Vdc or more (Standard) - for 1-5 V HART
Ambient Temperature Range
- -30° to 80° C (-22° to 176° F) with LCD Display
- -40° to 85° C (-40° to 185° F)
Approvals & Certifications
- IEC 61508: 2000, SIL 2 Capability for Single Transmitter Use, SIL 3 Capability for Dual Transmitter Use
- Leak Test
- Material Certificate
- Pressure Test
Approvals & Certifications
- ATEX Flameproof, Intrinsically Safe
- CSA Explosion-proof & Intrinsically Safe
- EMC EN 61326-1 Class A, EN 61326-2-3, EN 61326-2-5 (For Fieldbus)
- FM Explosion-proof & Intrinsically Safe Approval
- IEC Ex Intrinsically Safe & Flameproof Approval
- NAMUR NE43
- PED 2014/68/EU
- PED 97/23/EC
BSP Connection
- 1/2" BSPT Female
- 1/4" BSPT Female
Burst Pressure
- psi: 10,000 (MPa: 69, bar: 690) - for Wetted Parts Material S
- psi: 6,800 (MPa: 47, bar: 470) - for Wetted Parts Material Other Than S
Cable Material
- Polyethylene Insulated PVC Sheathed
Communication
- BRAIN
- FOUNDATION Fieldbus
- HART
- PROFIBUS PA
Consumption
- 0.96-3 mA - Power
- 27 mW - Power
Current
- 6,000 A, Maximum
Damping Adjustment
- 0 to 100 seconds
Diagnostics
- Configuration Error
- CPU Failure
- Hardware Failure
- Over-Range Error
- User Configurable Process Alarm for Pressure
Diaphragm Material
- Hastelloy® C-276
Display
- 10-Segment User-configurable Signal Characterizer for 4-20 mA Output - Signal Characterizer
- 5-Digit Numerical Display
- 6-Digit Unit Display
- Bar Graph
- LCD Display
Distance
- 0 to 2 Kilometers (1.25 Miles) when Using CEV - BRAIN Communication Distance
Drain, Vent Valves & Plug
- 316 Stainless Steel
- Hastelloy® C-276
- Monel®
- Super Duplex Stainless Steel
Electrical Connectors
- 1/2" NPT Female
- Blind Plug
- G 1/2" Female
- M20 Female
Enclosure Finish
- Anti-Corrosion Coating
- Deep Sea Moss Green Paint (Munsell 0.6 GY3.1/2.0 or its Equivalent)
- Polyurethane Paint
Enclosure, Body Material
- ASTM CF-8M Stainless Steel
- Low Copper Cast Aluminum Alloy
Environmental Protection
- IP66
- IP67
- NEMA 4X
Fill Material
- Fluorinated Oil
- Silicone
Flange Material
- ASTM CF-8M - Cover Flange
- Hastelloy® C-276 Equivalent - Cover Flange
- Monel® - Cover Flange
- Super Duplex Stainless Steel Equivalent - Cover Flange
Gasket Material
- Fluorinated Rubber - Process Connector
- Gold-Plated 316L Stainless Steel - Capsule Gasket
- PTFE Teflon - Process Connector
- Teflon-Coated 316L Stainless Steel
Humidity
- 0 to 100% Relative Humidity
Hysteresis
- ± 0.05% of Span
Input Impedance
- 10 KiloOhms or more at 2.4 kHz - Communicating Device
Length
- 4.6" (119 mm) - Long Vent
Linearization
- ± 0.055% of Span
Load
- 0 to 1,290 ohms - for Operation - for 4-20 mA HART/BRAIN
- 0.22 µF or less - Load Capacitance
- 250 to 600 ohms for Digital Communication - for 4-20 mA HART/BRAIN
- 3.3 MH or less - Load Inductance
Materials of Construction
- 304 Stainless Steel - Mounting Bracket
- 316 Stainless Steel - Name Plate & Tag & Vent, Mounting Bracket
Maximum System Pressure
- psi: 2,300 (kPa: 15,860, bar: 159)
Mounting
- 2" Pipe Mounting Bracket
Mounting Position Effect
- Tilting up to 90° will cause Zero Shift up to 0.4 kPa
NACE & NIST
- NACE MR-0103
NPT Connection
- 1/2" NPT Female
- 1/4" NPT Female
Nut & Bolt Material
- 316L Stainless Steel
- 660 Stainless Steel
- B7 Carbon Steel
O-Ring Material
- Buna-N - Cover O-Ring
- Fluororubber (Optional) - Cover O-Rings
Operating Temperature
- -20° to 80° C (-4° to 176° F) - Oil-prohibited Use
Output
- 0.9-5.4 Vdc
- 1-5 Vdc (3 or 4-Wire Low Power with HART)
- 3.6-21.6 mA
- 3.8-20.5 mA
- 4-20 mA DC (2-Wire)
Output Load
- 1 MegaOhm or Greater (Meter Input Impedance) - for 1-5 V HART
Overpressure & Static Pressure Limits
- Psi: 2,300 (kPa: 16,000, bar: 160) - Capsule H & A, Maximum
- psi: 3,600 (kPa: 25,000, bar: 250) - Capsule B, Maximum
Power
- 24 Vdc
Power Supply Effect
- ± 0.005% Per Volt (from 21.6 to 32 Vdc, 350 ohms)
Pressure Range
- bar: -1 to 160
- kPa: -100 to 16,000
- psi: -14.5 to 2,300
Pressure Type
- Gauge
Process Connection Material
- ASTM CF-8M
- Hastelloy® C-276 Equivalent
- Monel®
- Super Duplex Stainless Steel Equivalent
Process Temperature
- -40° to 120° C (-40° to 248° F)
Repeatability
- ± 0.055% of Span
Response Time
- 150 milliseconds for H Capsule with Wetted Parts Material Code H, M, T, A, D, B & W
- 90 milliseconds
Screw Material
- 316 Stainless Steel - Zero-Adjustment Screw & Set Screws
Stability
- ± 0.1% of URL Per 7-Years
Supply Pressure - Maximum
- Inches WC: 2,000 - Capsule H
- psi: 2,300 (MPa: 16, bar: 160) - Capsule B
- psi: 500 (MPa: 3.5, bar: 35) - Capsule A
- psi: 72.52 (kPa: 500, bar: 5) - Capsule H
Supply Voltage
- 10.5-30 Vdc - Intrinsically Safe, Typical N, or Non-Incendive Typical (4-20 mA HART/BRAIN)
- 10.5-32 Vdc - Lightning Protector (4-20 mA HART/BRAIN)
- 10.5-42 Vdc - General Use & Flameproof Typical (4-20 mA HART/BRAIN)
- 16.6 Vdc Minimum - Digital Communications, BRAIN & HART
- 24 Vdc, 0 to 550 ohms Load
- 9-28 Vdc - General Use & Flameproof Typical for 1-5 V HART
- 9-32 Vdc - Transmitter Power for Fieldbus Communication Typical
Temperature Effect
- ± (0.083% of Span + 0.014% of URL) Per 28° C (50° F) - Capsule A & B Ambient Temperature Effects
- ± (0.083% of Span + 0.02% of URL) Per 28° C (50° F) - Capsule H Ambient Temperature Effects
Update Time
- 45 milliseconds - Pressure
Vibration Effect
- <± 0.1% of URL - IEC60770-1 Field with General Application or Pipeline with Low Vibration Level (10-60 Hz, 0.15 mm Displacement / 60-500 Hz, 2 G)
- < 0.1% of URL - IEC60770-1 Field or Pipeline with High Vibration Level (10-60 Hz, 0.21 mm Displacement / 60-2,000 Hz, 3 G)
Wetted Materials
- 316L Stainless Steel - Capsule
- F316L Stainless Steel
- Hastelloy® C-276 - Capsule
- Monel® - Capsule
- Tantalum - Capsule
Zero Offset
- External Zero is Continuously Adjustable with 0.01% Incremental Resolution of Span
Documentation
Product Manuals
Certificate
Product Drawing
Specification
Technical Information
- FGP-110 5 .us.pdf 717 KB
- FGP-120 4 .us.pdf 1.0 MB
- FGP-140 5 .us.pdf 813 KB
- FGP-150 4 .us.pdf 708 KB
- FGP-170 3 .us.pdf 627 KB
- FGP-210.us.pdf 584 KB
- FGP-220 2 .us.pdf 493 KB
- FGP-230 2 .us.pdf 756 KB
- FGP-250 2 .us.pdf 743 KB
- FGP-260 2 .us.pdf 658 KB
- FGP-270 2 .us.pdf 634 KB
- FGP-280 1 .us.pdf 1.1 MB
- FGP-300 1 .us.pdf 2.2 MB
- FGP-310 1st edition .us.pdf 811 KB
- TI01C25A05-01EN.pdf 658 KB
- TI01C25A05-21EN.pdf 2.6 MB