OD1000 Displacement Measurement Sensor
Brand: SICK CanadaWith its sensing range of up to 1 m, the OD1000 displacement measurement sensor sets new standards in precise distance measurement with triangulation. Its high performance data ensures a smooth production process and allows a high level of productivity in a wide range of applications, almost regardless of the surface quality, color, or object structure. The clear OLED display with four operating keys simplifies commissioning and optimizes the machine availability.
As a standalone device with integrated evaluation, IO-Link interface, and additional functions, the OD1000 simplifies machine integration, saves additional evaluation effort, and paves the way for sustainable production.
At a glance
- Large measuring range of up to 1 m
- Simple setting via OLED display or SOPAS configuration software
- Standalone device without external amplifier unit
- Rugged metal housing
- Adjustable analog output (mA/V) and push-pull digital output with IO-Link
- Precise measurement regardless of color or surface
- Versatile mounting possibilities
- Optimization of the process quality due to high precision and linearity over the entire measuring range
- Quick commissioning due to variable mounting and innovative operating concept
- Simple and cost-saving integration via OLED display and IO-Link interface
- Suitable for harsh ambient condition due to rugged metal housing
- High machine availability thanks to reliable, quick, and precise measurement results on a wide range of surfaces
- Intelligent measured value filter and analysis algorithm for safe and stable measurement in every application
Specifications
Brand
Certifications & Approvals
- CE
- TUV
- EAC
Measuring Range
- 200 to 1,000 mm
Linearity
- ± 1.5 mm
Repeatability
- 0.4 mm
Response Time
- ≥ 1.5 ms
Output Time
- ≥ 0.33 ms
Measuring Frequency
- ≤ 3 kHz
Digital Output
- 2 x Push-pull: PNP/NPN
Light Source
- Laser, Red
Type of Light
- Visible Red Light
Communication
- IO-Link V1.0
- IO-Link V1.1
Analog Output
- Current Output
- Voltage Output
Operating Temperature
- Ambient -10° to 50° C at Us = 24 V
Documentation
Product Manuals
Brochure
- OD1000 COM2 technical information pdf 534 KB
- Distance Sensors Precision for Measuring Tasks pdf 1.5 MB
- FROM MICRON TO MILE. IN ALL DIMENSIONS. pdf 657 KB
- Laser Triangulation Sensors DT20 Hi, OD Value, OD1000, OD Mini, OD Max, OD Precision, OD5000 pdf 6.1 MB
- OD1000 com3 technical information pdf 535 KB
- OD1000 com3 technical information pdf 609 KB
- Precision meets Quality Our solution for measurement sensors pdf 3.2 MB