MCS300P Multicomponent Analysis System

Brand: SICK Canada

The MCS300P HW is a hot/extractive analyzer system for measurement of gases. It measures IR- or VIS-active components with variable measuring ranges for monitoring and controlling of combustion and flue gas conditioning. The heated system components prevent a temperature drop below the water and acid dewpoint. 

This results in lower maintenance and higher reliablity and long-time stablity of the system, also under rugged and demanding conditions. Automatic adjustment functions, easy operation concept and modern communication protocols results in a quick and easy integration into a local control system network.

At a glance
  • Simultaneous measurement of up to 6 components plus O2
  • Measurement gas flow monitoring and measurement gas pressure detection
  • Temperature of the system components up to 200° C
  • Automated sample point switching for up to 3 sample points (optional)
  • Automated adjustment to the zero and reference point
  • Integrated adjustment of the device without test gas (optional)
  • Extended operation via PC and SOPAS ET software
  • Flexible I/O module system
Features
  • Economic, automatic adjustment without expensive test gases
  • Easy remote control by integration in existing networks
  • Automatic control of the complete measuring system and probe
  • Low maintenance and reliable due to hot measurement
  • In combination with probe SCP3000 also for measurements at high dust loads and high temperatures
  • Short response time due to high sample gas flow

Specifications

Certifications & Approvals

  • CE

Gas Flow Rate

  • 150 to 800 l/h

Measured Value

  • CO, CO2, HCl, H2O, NH3, NO, NO2, N2O, SO2, O2

Measuring Range

  • SO2: 0 to 200 ppm / 0 to 10 Vol%
  • O2: 0 to 1 Vol% / 0 to 21 Vol%
  • N2O: 0 to 500 ppm / 0 to 7,500 ppm
  • NO2: 0 to 500 ppm / 0 to 4,000 ppm
  • NO: 0 to 750 ppm / 0 to 15,000 ppm
  • NH3: 0 to 550 ppm / 0 to 5,000 ppm
  • H2O: 0 to 1 Vol% / 0 to 60 Vol%
  • HCl: 0 to 700 ppm / 0 to 12,000 ppm
  • CO2: 0 to 20 Vol% / 0 to 100 Vol%
  • CO: 0 to 800 ppm / 0 to 5 Vol%

Response Time

  • ≤ 150 s

Process Temperature

  • ≤ 1,300 °C Depending on sampling probe

Sample Gas Temperature

  • ≤ 220 °C

Process Pressure

  • 800 to 1,200 hPa

Ambient Temperature

  • With Cooling Device 5° to 45° C
  • 5° to 35° C

Ambient Humidity

  • ≤ 80% Non-condensing

Environmental Protection

  • IP43

Communication

  • Modbus
  • Ethernet

Indication

  • LC Display