VJQ7 Analog to Pulse Converter

Brand: Yokogawa

The VJQ7 is a plug-in type Analog to pulse converter that converts DC current or DC voltage signal into isolated transistor-contact pulse or contactless AC switch pulse.
Features
  • Either Pulse Output, Communication Function (RS-485) or Alarm Output (2 Relay Contacts) is Selectable as Output-2
  • Various Parameters Such as Input Ranges Can be Set and Modified Through a PC (VJ77) or Handy Terminal (JHT200 and the Like)

Specifications

Accuracy

  • ± 0.1% of Span

Alarm

  • 0 to 100% of Input Range - Alarm Setting Range
  • High/Low - Alarm Operating Direction

Approvals & Certifications

  • CAN/CSA C22.2 No.61010-1
  • CE EN 61326-1
  • EMC
  • KC
  • UL 61010-1

Communication

  • 2-Wire Half-Duplex
  • Baud Rate: 1,200, 2,400, 4,800, 9,600 bit/sec
  • Data Length: 7-bits, 8-bits
  • EIA RS-485
  • LADDER Communication Protocol
  • Modbus ASCII/RTU Communication Protocol
  • PC-Link Communication Protocol
  • PC-Link with Sum Communication Protocol
  • Stop Bit: 1-bit, 2-bits

Delay Time

  • 1 to 999 seconds - Alarm ON & OFF Delay Setting Range

Display

  • LED Display - Alarm Operation

Dissipation

  • 2.4 W at 24 Vdc & 110 Vdc - Power Dissipation
  • 4.5 VA at 100 Vac - Power Dissipation
  • 6.3 VA at 200 Vac - Power Dissipation

Distance

  • 3,937 feet (1,200 meters) - Maximum

Electrical Connectors

  • M3 Screw Terminal

Electrical Rating

  • 30 Vdc at 1 A - Contact Capacity

Enclosure, Body Material

  • Modified Polyphenylene Oxide

Frequency

  • 0.001 to 2,000 Hz - Output Frequency

Humidity

  • 5 to 90% Relative Humidity Non-Condensing

Hysteresis

  • 0 to 100% of Input Range - Hysteresis Setting Range

Input

  • 0-50 mA DC, Span is 5 mA or more - Code A
  • -1 to 1 V (L Range), Span is Under 0.5 V
  • -10-10 V (H Range), Span is Under 5 V
  • -10-10 Vdc, Span is 0.1 V or more - Code 1
  • 100-240 Vac/dc (-15%, 10%) 50/60 Hz - Power Supply Input Voltage
  • 15-30 Vdc (± 20%) - Power Supply Input Voltage
  • -5 to 5 V (M Range), Span is Under 2.5 V

Insulation Resistance

  • 100 MegaOhms at 500 Vdc between Input, Output-1, Output-2, Power Supply & Ground Mutually

Load

  • 100 Vac / 200 mA - Contactless AC Switch, Maximum
  • 30 Vdc / 200 mA - Open Collector, Maximum

Mounting

  • Dedicated VJ Mounting
  • DIN Rail
  • Wall Mounted

Output Format

  • 2 Relay Contact - Alarm Output
  • Contactless AC Switch
  • Open Collector

Power Supply

  • 100-240 Vac/dc, 50/60 Hz - Power Supply Rated Voltage
  • 15-30 Vdc - Power Supply Rated Voltage

Power Supply Effect

  • ± 0.1% of Span or less - Effect of Power Supply Voltage Fluctuation of 85-264 Vac/dc (47 to 63 Hz), 12-36 Vdc

Pulse Range

  • 0.1 to 500 milliseconds - Pulse Width Time

Resistance

  • 1 MegaOhms (100 KiloOhms when Power Off) - Input Resistance for DC Voltage Signal
  • 100 ohms (External Shunt Resistor) - Input Resistance for DC Current Signal

Resolution

  • 0.1%, 4 Significant Digits - Setting Resolution
  • 1 second - Setting Resolution

Response Time

  • 150 milliseconds

Supply Voltage

  • 1,000 Vac/minute - withstand Voltage between Input & Output-2 at Alarm Output & between Output-1 & Output-2
  • 2,000 Vac/minute - withstand Voltage between Input, (Output-1, Output-2), Power Supply, & Ground Mutually

Temperature Effect

  • ± 0.2% or less of Span for a Change of 10° C (18° F) - Effect of Ambient Temperature Change

Temperature Range

  • 0° to 50° C (32° to 120° F)

Zero Offset

  • 50% or more - Zero Elevation when Output Frequency is ≤ 1 kHz

show more