ZIRKOR302 In-situ Gas Analyzers

Brand: SICK Canada

The ZIRKOR302 in-situ gas analyzer from SICK can be relied upon to measure oxygen quickly even at increased temperatures. Thanks to the flow sensor measurement principle, it does not require expensive test gases – ambient air is sufficient. The analyzer is not an ignition source in the measurement gas due to its safety-related construction. The optional evaluation unit allows you to operate up to three analyzers.

At a glance
  • Innovative flow sensor measurement principle
  • Fixed physical zero point and linear measurement signal
  • All parts in contact with gas are heated
  • Version for high temperatures available
  • Short response time
  • Operation of up to three analyzers via one evaluation unit
Features
  • Automated testing and adjustment with ambient air
  • No expensive test gases required
  • Reignition into the measurement gas not possible because the sensor is located outside the measurement gas
  • Process monitoring even at high temperatures
  • Quick measurement directly in the process for timely control

Specifications

Certifications & Approvals

  • CE

Enclosure Rating

  • IP67/NEMA 4X
  • IP65/NEMA 4X

Gas Flow Rate

  • 0.5 l/h

Measuring Range

  • Certified: 0 to 21 Vol.%
  • 0 to 10 Vol.% / 0 to 25 Vol.%

Response Time

  • ≤ 20 s, With Standard Gas Sampling Device, Length = 1 m

Process Temperature

  • Ceramics Probe: 0° to 1,400° C
  • Inconel Probe: 0° to 950° C
  • Stainless Steel Probe: 0° to 700° C

Process Pressure

  • 700 to 1,100 hPa

Ambient Temperature

  • -20° to 55° C

Storage Temperature

  • -40° to 85° C

Power Supply

  • 115 Vac / 230 Vac, 48 to 62 Hz, Power Consumption ≤ 250 VA

Material of Construction

  • Stainless Steel 1.4571

Communication

  • Serial
  • RS-232
  • CAN Bus
show more