VJHR Single & Dual Reverse Output Isolator

Brand: Yokogawa

The VJHR is a compact, plug-in type isolator that converts DC current or DC voltage signals into isolated and inverted DC current or DC voltage signals.

Specifications

Accuracy

  • ± 0.1% of Span

Approvals & Certifications

  • CE
  • EMC Standard: EN 61326

Consumption

  • 2.1 W at 110 Vdc - Power Consumption
  • 2.2 W at 24 Vdc - Power Consumption
  • 4.2 VA at 100 Vac - Power Consumption
  • 6.1 VA at 200 Vac - Power Consumption

Current

  • 100 µA-150 mA for Span (DC) - Input Current Signal
  • 1-24 mA for Span (DC) - Output Current Signal

Electrical Connectors

  • M3 Screw Terminals

Enclosure, Body Material

  • Modified Polyphenylene Oxide

Humidity

  • 5 to 90% Relative Humidity, Non-Condensing - Operating Humidity Range

Input

  • ± 30 Vdc - Allowable Input Voltage
  • 0 to 100 mVdc
  • 0 to 150 mA DC
  • -300 to 300 Vdc

Insulation Resistance

  • 100 MegaOhms Minimum at 500 Vdc between Input, Output-1, Output-2, Power Supply & Grounding Terminals Mutually

Mounting

  • Base Mounting (VJCE) - Dedicated VJ Mounting
  • DIN Rail Mounting
  • Wall Mounting

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Operating Voltages

  • 12-36 V
  • 85-264 V

Output

  • 0 to 100 mVdc
  • 0 to 24 mA DC
  • -10-10 Vdc

Power Supply

  • 100-240 Vac/dc (-15%, 10%) 50/60 Hz - Supply Rated & Input Voltage Range
  • 15-30 Vdc (± 20%) - Supply Rated & Input Voltage Range

Power Supply Effect

  • Up to ± 0.1% of Span for the Regulation within Allowable Range of Each Supply Voltage Range - Effects of Power Line Regulation

Resistance

  • 1 MegaOhm - DC Voltage Input Resistance During Power On
  • 10 KiloOhms - DC Voltage Input Resistance During Power Off
  • 100 to 1,000 ohms - DC Current Input Resistance
  • 2 to 250 KiloOhms Minimum - DC Voltage Allowable Load Resistance
  • 350 to 15,000 ohms, Maximum
  • 800 KiloOhms - DC Voltage Input Resistance During Power Off

Response Time

  • 150 milliseconds, 63% Response (10 to 90%)

Span & Zero Adjustments

  • -5 to 5% - Zero Adjustment
  • 95 to 105% - Span Adjustment

Supply Voltage

  • 1,000 Vac for One Minute between Output-1 & Output-2 Terminals - withstanding Voltage
  • 10 mV-20 V for Span (DC) - Output Voltage Signal
  • 10 mV-600 V for Span (DC) - Input Voltage Signal
  • 2,000 Vac for One Minute between Input, (Output-1 & Output-2), Power Supply & Grounding Terminals Mutually - withstanding Voltage

Temperature Effect

  • Up to ± 0.15% of Span Per 10° C (18° F) - Effects of Ambient Temperature Variations

Zero Offset

  • 0 to 200% for Output Current Signal - Zero Elevation
  • 0 to 73% for Input Current Signal - Zero Elevation
  • -100 to 200% for Output Voltage Signal - Zero Elevation
  • -80 to 73% for Input Voltage Signal - Zero Elevation

Documentation

show more